CORROSION INHIBITOR CI 3023

Product code: RXSOL-34-8165-211

RXSOL Corrosion Inhibitor CI 3023 is a film-forming corrosion inhibitor

The product is intended to reduce internal corrosion of compatible metallic surfaces in oil and gas production and pipeline transportation systems.

Film-forming corrosion inhibitors work by adsorbing onto metal surfaces and forming a protective barrier that reduces contact between corrosive fluids and the underlying metal.

RXSOL Corrosion Inhibitor CI 3023, code RXSOL-81-8165-211.

THINK CHEMICAL THINK RXMARINE

Application

RXSOL TECHNICAL PRODUCT BULLETIN

CORROSION INHIBITOR KI 3939

Film-Forming Corrosion Inhibitor for Oil & Gas Production and Pipeline Protection

RXSOL Equivalent Product: Corrosion Inhibitor CI 3023 RXSOL Product Code: RXSOL-81-8165-211 Product Category: Oilfield Chemicals / Pipeline Corrosion Inhibitors Application: Oil & Gas Production, Hydrocarbon Pipelines and Industrial Corrosion Protection

Major Applications

Application

Purpose

Crude Oil Pipelines

Internal corrosion protection

Oil & Gas Production Lines

Control of corrosion in production fluids

Flowlines

Protection of compatible carbon steel surfaces

Gathering Pipelines

Corrosion management during fluid transportation

Production Equipment

Reduction of corrosion-related metal deterioration

Industrial Hydrocarbon Systems

Corrosion control where validated

Suitability for CO₂-containing or H₂S-containing fluids must be confirmed through representative corrosion testing. Inhibitor performance depends on fluid composition, temperature, flow conditions and metallurgy.

 
 

Dosage

Working Mechanism

The intended corrosion inhibition mechanism involves:

Surface Adsorption: Active inhibitor components adsorb onto compatible metal surfaces.

Protective Film Formation: A barrier film reduces exposure of the metal to corrosive components.

Corrosion Rate Reduction: The protective layer helps reduce electrochemical corrosion reactions.

Film Maintenance: Continuous injection may be required to replenish the inhibitor film under flowing conditions.

Recommended Dosage

Application

Preliminary Dosage

Continuous Pipeline Injection

6–12 ppm, supplier-published range

High-Corrosion Systems

Determine through laboratory and field trials

Initial Film Establishment

Site-specific treatment programme

Batch Treatment

Subject to system design and validation

Example: For a pipeline carrying 100 m³/hour of fluid, a treatment rate of 10 ppm by mass corresponds to approximately 1 kg/hour of inhibitor if the treated fluid density is assumed to be 1,000 kg/m³.

For other fluid densities, the required inhibitor mass flow changes accordingly.

The actual injection volume also depends on the inhibitor's density.