Categories: Tank Cleaner-20
Product Short Description:

Phenol Cleaner

Product Description:
Product Application:

Phenol (Cleaning Procedure)

Direct after discharge flush lines and tanks thoroughly with hot fresh water or demi water and recirculate. This is done to bring the freezing point down prior to the prescribed tank cleaning procedure. Demi water will be used if the pre-wash quantity can be pumped ashore.
 

  1. Butterworth the tanks 1, 5-2 hours with hot seawater or freshwater (80°C).
     
  2. Prepare the following cleaning solution in freshwater:0.4 % RXSOL CTC-VOLC
    Butterworth the tank 1 hour by recirculation with a temperature of approx 70°C. The
    necessary temperature can be achieved/maintained by means of heating coils, or 
    going via the Butterworth heater. The solution can be used for 1 to 4 tanks.
     
  3. Butterworth the tank for 0, 5 hours with hot fresh water.
     
  4. Ventilate, mop and dry the tank.
  • Instead of recirculation cleaning the RXSOLCTC-VOLC can be as well injected into the Butterworth system (see cleaning method 3).
Product Dose:
Product Note:
Free Delivery / Supply Locations : 
Oman, Bahrain, Abu Dhabi, Ajman, Al Ain, Dubai, Ras Al-Khaimah, Ras al Khaimah, Fujairah, Sharjah, Umm Al Quwain, Fujairah, Ruwais, Mina (Port) Zayed, Khalifa Port, Kizad, Port Rashid, Jebel Ali Port, DP WORLD, Jebel Ali Free Zone, Khor Fakkan Container Terminal, Port Rashid, Jebel Ali Port, Mina Kalid Port, Khor Fhakan Port ( Khawr Fakkan, Khawr al-Fakkan ), Sharjah Creek, Ajman, Port of Hamriyah, Mina Zayed Port, Mussafah port, Khalifa Port, Umm al-Nar Port, Um Al Quwain Port, Saqr Port, Port of Fujairah, Dibba Port, Jebel Dhanna, Mina Al Hamriya, Mina Rashid, All United Arab Emirates