Catalyzed liquid oxygen scavenger, This formulation is especially effective way of protecting ferrous and aluminum metals from corrosion due to adverse environmental conditions such as high heat and humidity, seawater or other harsh environments , for b
To decrease oxygen on LP boiler Oxygen Control Corroision Inhibitor is a catalyzed liquid oxygen scavenger ( free from Hydrazine ) , This formulation is especially effective way of protecting ferrous and aluminum metals from corrosion due to adverse environmental conditions such as high heat and humidity, seawater or other harsh environments , for boiler and steam line corrosion protection. As an additional benefit it will assist to neutralize dissolved cabon dioxide. It provides the required condition for the estabishment of a pasivity layer (magnetite) in the boiler and condensate system.
Powder Application:-
For average conditions the recommended dosage is 0.30 ounces (weight) per cubic foot (28 Liters) of enclosed space.( 300 g/cubic meter) Concentration can be increased to protect metals under more severe conditions. Powder is applied by air fogging or sprinkle and then the treated area is closed or sealed.
Liquid Application:-
For average conditions the recommended dosage as a solution is a 0.25% in water (based upon weight). This solution is recommended as a hydrostatic test fluid or as an additive to a final rinse in metalworking applications. Concentration can be increased to protect metals under more severe conditions. The treated area is then closed or sealed.
RXSOL-50-5007-025 The objective is to maintain a hydrazine residual between 0.05-0.2 ppm depending on operating pressure and boiler designe. Actual consumption is determined under operating conditions. A normal dosage is approximately 1 ltr. per day, depending of system layout.
Hydrazine is a convenient reductant because the by-products are typically nitrogen gas and water. Thus, it is used as an ANTIOXIDANT, an oxygen scavenger, and a corrosion inhibitor in water boilers and heating systems.
Hydrazine is mainly used as a foaming agent in preparing polymer foams
More about Water Boiler Treatment & Powder / liquid Inhibitors
scales are very damaging to the boiler because they interfere with the heat transfer and can lead to overheating and eventually, boiler rupture
By using this corrosion inhibitor / oxygen control the build up of sediment deposits and damaging corrosion of water boilers is greatly reduced. Our research and experience recomend to working water boilers at a rate of 0.5 to 1.0 percent of the weight of water in the system. This amounts to 4 up to 8 pounds of powder corrosion inhibitor in 100 gallons of water
COMMON NAME : Oxygen control corroision inhibito for FEROUS & ALUMINUM