Hydro-testing corrosion protection for Pipeline, Tank contains corrosion inhibitor, oxygen scavenger and biocide
Hydro Testing Corrosion Inhibitor RXSOL 4000 is a multicomponent, multifunctional formulation which prevents corrosion, microbiological growth in single product treatment programme. Inhibitor, corrosion, multicomponent, multifunctional: For prevention of corrosion and microbiological growth in water flood systems during hydrostatic testing and other applications.
PERFORMANCE:
CORROSION: Effectively prevents corrosion due to Carbon Dioxide, inorganic salts, dissolved oxygen & Hydrogen sulphide contamination from sour fluid or bacterial action. The inhibitor acts as a cathodic polarizer
MICROBIOLOGICAL GROWTH: Effectively prevents the metabolic function necessary for reproduction of the bacteria cell. Successfully prevents anaerobic/aerobic and sulphate reducing bacteria.
Hydro Testing Corrosion Inhibitor RXSOL can be fed directly or through chemical doses pump. Doses may vary with the quality of water to be treated and the residence time of the water in the system.
Actual consumption is determined under operating conditions.
Recommended Dosage of Hydro Testing Corrosion Inhibitor RXSOL 4000
Hydro Testing Corrosion Inhibitor RXSOL 4000 dosage levels typically are 500ppm for hydrotest operations and between 1000- 4000 ppm when used as a packer fluid inhibitor. The exact dose rate for a specific job would depend on the environment and fluid that the chemical was being deployed into. We are happy to advise on this if required.
Benefit / Advantage of Hydro Testing Corrosion Inhibitor RXSOL 4000
How to use Hydrotesting Corrosion Inhibitor Oxygen Scavenger Biocide RXSOL-43-4035-210
Corrosion inhibitor shall be dosed in the displacement water piping at the suction of main pump/ booster pump
Dose 2 to 3 ltr per 100 ltr water.
Contact time: Minimum 24 hours for effective passivation + biocidal effect
Temperature: Ambient to 50°C (higher temp improves kinetics but not essential)
Mixing: Ensure thorough circulation to distribute inhibitor uniformly
Water quality: Ideally should be low hardness and low chloride (<50 ppm Cl⁻ preferable)
Oxygen level: Target <1 ppm dissolved oxygen after treatment (check with DO meter if possible).
Flushing: After test, flush system thoroughly to remove chemicals.
When to consider HIGHER DOSAGE of RXSOL Hydrotesting Corrosion Inhibitor?
However if you are considering higher dosage, it should be under following conditions:
If hydrotest duration exceeds 7 days OR If high temperature (more than 50°C) - use 3% - 4% v/v
Additional points to take care: